AI data centres (AIDCs) need backup power that is instant, large and steadily lower in carbon. No single product achieves all three; the strongest solution combines five levers: battery-first response, lower-carbon fuels, coordinated generation and storage, on-site solar, and data that proves the results. MPMC, a Shanghai-based manufacturer of battery energy storage systems, generator sets and the EMS and SCADA that link them, supplies every lever from its own factories.
Five Levers for Lower-Carbon Backup
1. Battery-First Response
MPMC’s HBD-A battery energy storage systems integrate with the generator set array to provide UPS-level millisecond response, so short disturbances are covered silently and without emissions. Units from 125 kW / 261 kWh to 1,125 kW / 2,170 kWh use LFP 314Ah cells rated for 8,000 cycles at 90% depth of discharge, with liquid cooling, VSG, black start and grid-forming capability, and on-grid and off-grid switching on every model, with seamless switching available as an option.
2. Lower-Carbon Fuels for the Generator Sets
Selected Cummins models support HVO to EN 15940 and B20 blends, and MPMC’s platform also covers natural gas and biofuel at B35 and above. On MPMC’s 18 MW biodiesel project in Indonesia, B35 lowers lifecycle CO2 by up to 85% compared with petroleum diesel and complies with RED II and RFS standards. Natural gas generator sets reach electrical efficiency of at least 38%, and total energy utilisation of 80% or more where heat is recovered.
3. Generation and Storage Working as One
MPMC’s Twins Power MPME2700S-2-SC twin-engine diesel generator set, rated 2,702 kW / 3,377.5 kVA prime at 13.8 kV, dispatches its two Perkins engines according to load for up to 40% fuel saving at low load, and combines backup, peak shaving and EMS control. Paired with commercial and industrial battery storage, which handles peak shaving and valley filling, load support and smoothing of load fluctuations, it lets generation and storage complement each other. At ten off-grid stations in Dubai, the same principle of battery plus generator set operation cut daily fuel use by 10.56% and OPEX by about 20% per station.
4. On-Site Solar
HBD-A storage captures rooftop or campus PV and supplies it later, while DC-coupled HBD-DC 410 and HBD-DC 5000 models, with up to 5,015 kWh per unit, suit large solar-plus-storage installations. The same battery provides peak shaving and frequency regulation when it is not needed for backup.
5. Data That Proves the Results
MPMC’s self-developed SCADA provides real-time monitoring, automated monthly and annual reports and ten years of data retention under an SL3-level cybersecurity framework, giving operators the records they need for sustainability reporting, with Starlink satellite communication as a backup link.
Table 1. Five levers for low-carbon AIDC backup
Lever
MPMC solution
Carbon benefit
Battery-first response
HBD-A, 125-1,125 kW per unit
Short events covered without fuel
Lower-carbon fuels
HVO and B20 on selected Cummins models; B35+ biofuel
Up to 85% lower lifecycle CO2 with B35
Generation plus storage
Twins Power MPME2700S-2-SC with C&I storage
Up to 40% fuel saving at low load
On-site solar
HBD-A and HBD-DC storage
Renewable energy stored for later use
Measured results
SCADA with automated reports
Ten years of verifiable data

MPMC HBD-A Series HBD-1000-2000 containerised battery energy storage system.
How the Levers Combine in Practice
A typical low-carbon AIDC design places HBD-A storage between the grid connection and the critical load for instant response and daily peak shaving, sizes containerised generator sets of 1,000 kVA to 3,000 kVA per unit, or Twins Power units, for extended outages on lower-carbon fuel, and adds solar wherever roof or land space allows. One EMS coordinates the whole system, so the battery covers the events it is sized for and the generator sets start when an outage runs on. Every generator set is load-tested from 0% to 110% in MPMC’s CNAS-accredited test centre, including a room that simulates 40°C or 50°C ambient.
Table 2. MPMC references behind each part of the architecture
Reference
Scale
Relevance
Data centre, UAE
3 MW
MTU-powered sets at 6 kV
Changhang Power Station (data centre), UAE
12 MW
MTU-powered data-centre generation
Data-centre backup, United States
36 MW
Large-scale backup power
8 MWh BESS delivered to Europe
5 × 2,097 kWh
HBD-1000-2000A, dual-PCS architecture
Green power plant, Hungary
8 MWh
Frequency regulation, peak shaving, load balancing

MTU-powered MPMC generator set built for a data centre in the UAE.
Planning Low-Carbon AIDC Backup With MPMC
• Set the share of events to be covered by storage
• Choose generator set fuel, including HVO or biofuel
• Consider Twins Power units for generation-storage coordination
• Plan solar and reporting requirements
• Contact MPMC at sales@mpmc-china.com or WhatsApp +86 150 0085 4420 for a low-carbon AIDC backup proposal